Hampton Bay 7136-02 Ventilating Fan Specs
Spanning single SKU 7136-02, Hampton Bay 7136-02 logs Fan Efficacy 3.9 CFM/W inside a standard residential footprint built for 140.0 CFM. Out of 900 certified U.S. ventilating fans, this Bathroom/Utility Room model achieves higher-draw: #688 / 900 — tied with 51 peers, scores higher efficiency than 17.9% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #688 of 900
- Capacity
- 140.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Hampton Bay 7136-02?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | 7136-02 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 140.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2019 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 3.9 CFM/W | Bathroom/Utility Room | 6.00 inch diameter |
Which ventilating fans match 7136-02 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs 7136-02 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| HomeWerks Worldwide 7136-02 | Bathroom/Utility Room | Not listed | Not listed | 140.0 CFM | Not listed | 1 |
| Elica EAL330 | Range Hood | Not listed | Not listed | 141.1 CFM | Not listed | 1 |
| AUPU B6-13 | Bathroom/Utility Room | Not listed | Not listed | 130.0 CFM | Not listed | 2 |
| Broan QT130L | Bathroom/Utility Room | Not listed | Not listed | 130.0 CFM | Not listed | 2 |
| KOHLER 34454 | Bathroom/Utility Room | Not listed | Not listed | 130.0 CFM | Not listed | 2 |
Does 7136-02 carry R-600a, duct, or installation boundaries?
7136-02 (Bathroom/Utility Room, 3.9 CFM/W) vents humid indoor air outdoors via 6.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- 7136-02
Should you repair 7136-02 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What is the projected 15-year power cost for Hampton Bay 7136-02?
Multiplying certified ENERGY STAR status by the U.S. EIA residential average of 18.16 cents/kWh places Hampton Bay 7136-02 running cost at scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) over its 15-year NAHB component life.
Does Hampton Bay 7136-02 outperform the ventilating fans category median?
Against a category median of 0.0 kWh/yr across 900 chassis, Hampton Bay 7136-02 stands at rank #688: -0.7 CFM/W (-15.2%); Rank #688 / 900 (tied with 51 at 3.9 CFM/W).
What is the 50% cost threshold for Hampton Bay 7136-02 repairs?
Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 7.5 years.
Which installations do NOT fit Hampton Bay 7136-02?
Skip Hampton Bay 7136-02 if your cabinet cutout cannot fit OEM cutout blueprint, if 140.0 CFM cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.
Why are 1 SKU variants grouped under Hampton Bay 7136-02?
Manufacturers file separate paint letters such as 7136-02 for one mechanical chassis; grouping them shows true certified ENERGY STAR status and 140.0 CFM specs without duplicate model clutter.
Which hazards forbid uncertified work on Hampton Bay 7136-02?
Always shut off the electrical breaker and water shutoff valve before opening 7136-02 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
Can you swap Hampton Bay 7136-02 without modifying kitchen framing?
Inspect the 5 nearest peers matched to OEM cutout blueprint and 140.0 CFM; selecting a peer matching 7136-02's width avoids countertop or cabinet trim alterations.
Why screen recall notices for Hampton Bay 7136-02 before paid service?
Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)