HomeWerks Worldwide 7107-03 Ventilating Fan Specs
Spanning single SKU 7107-03HW, HomeWerks Worldwide 7107-03 logs Fan Efficacy 4.1 CFM/W inside a standard residential footprint built for 110.0 CFM. Out of 900 certified U.S. ventilating fans, this Bathroom/Utility Room model achieves higher-draw: #641 / 900 — tied with 21 peers, scores higher efficiency than 26.4% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #641 of 900
- Capacity
- 110.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for HomeWerks Worldwide 7107-03?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | 7107-03 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 110.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2022 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 4.1 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |
Which ventilating fans match 7107-03 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs 7107-03 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Broan AER110RGBL | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| RAB CEP10 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| RAB CEP10SNL | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Tech Drive TD-BF-07-PLU | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Tech Drive TD-BF-25L-5CCT(BL) | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
Does 7107-03 carry R-600a, duct, or installation boundaries?
7107-03 (Bathroom/Utility Room, 4.1 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- 7107-03HW
Should you repair 7107-03 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running HomeWerks Worldwide 7107-03 cost each year?
At 18.16 cents/kWh (EIA August 2026), HomeWerks Worldwide 7107-03 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically 7107-03HW.
How efficient is HomeWerks Worldwide 7107-03 compared with federal ceilings?
Measured against 10 CFR 430 certified, HomeWerks Worldwide 7107-03 holds rank #641 out of 900 U.S. ENERGY STAR ventilating fans: -0.5 CFM/W (-10.9%) vs median 0.0 kWh/yr.
Which minor parts are exceptions to replacing HomeWerks Worldwide 7107-03?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is HomeWerks Worldwide 7107-03 a poor match for a remodel?
Avoid HomeWerks Worldwide 7107-03 if 110.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the HomeWerks Worldwide 7107-03 line use identical energy?
Yes; every listed finish — including 7107-03HW — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 110.0 CFM volume.
What safety codes restrict HomeWerks Worldwide 7107-03 disassembly?
Always shut off the electrical breaker and water shutoff valve before opening 7107-03 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for HomeWerks Worldwide 7107-03?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on HomeWerks Worldwide 7107-03?
Inspect the inner liner wall, door rim, or tub flange via the HomeWerks Worldwide serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)