Skip to main content
Ventilating Fans · Rank #766 of 900

KOHLER 34455 Ventilating Fan Specs

Spanning 2 finish SKUs including 34455, 34455-NA, KOHLER 34455 logs Fan Efficacy 3.7 CFM/W inside a standard residential footprint built for 130.0 CFM. Out of 900 certified U.S. ventilating fans, this Bathroom/Utility Room model achieves higher-draw: #766 / 900 — tied with 23 peers, scores higher efficiency than 12.3% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#766 of 900
Capacity
130.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #766 / 900 (tied with 23 at 3.7 CFM/W)
vs Ventilating Fans Median -0.9 CFM/W (-19.6%) EPA certified comparison
Federal Metric (Fan Efficacy) 3.7 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for KOHLER 34455?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

KOHLER 34455 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric 34455 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 130.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2024 2 SKUs Consolidates 2 finish variants
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 3.7 CFM/W Bathroom/Utility Room 4.00 inch depth X 0.00 inch width

Which ventilating fans match 34455 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs 34455 Capacity Cutout Dimensions SKUs
Whirlpool Corporation WVU7130J Range Hood Not listed Not listed 130.0 CFM Not listed 1
AUPU B6-13L Bathroom/Utility Room Not listed Not listed 130.0 CFM Not listed 1
Broan PM400 Range Hood Not listed Not listed 130.0 CFM Not listed 1
AUPU B6-13 Bathroom/Utility Room Not listed Not listed 130.0 CFM Not listed 2
Broan QT130L Bathroom/Utility Room Not listed Not listed 130.0 CFM Not listed 2

Does 34455 carry R-600a, duct, or installation boundaries?

34455 (Bathroom/Utility Room, 3.7 CFM/W) vents humid indoor air outdoors via 4.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • 34455
  • 34455-NA

Should you repair 34455 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What does KOHLER 34455 consume in kWh and dollars?

EPA data records certified ENERGY STAR status for KOHLER 34455, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 2 consolidated SKU finishes.

How far below the federal ceiling is KOHLER 34455?

It posts 10 CFR 430 certified and places #766 of 900 ventilating fans: -0.9 CFM/W (-19.6%) relative to the 0.0 kWh/yr median.

At what age does KOHLER 34455 fail the 50% repair test?

Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.

Which buyers should skip KOHLER 34455?

Skip 34455 if cabinet openings cannot clear OEM cutout blueprint, if 130.0 CFM misses family sizing, or if commercial heavy-use durability is required.

Are 34455, 34455-NA mechanically the same model?

Yes; cosmetic finish trims (2 total SKUs) share identical certified ENERGY STAR status efficiency, 130.0 CFM interior rating, and chassis assemblies.

Which safety boundaries restrict KOHLER 34455 DIY work?

Always shut off the electrical breaker and water shutoff valve before opening 34455 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Which peer alternatives match KOHLER 34455?

Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 130.0 CFM capacity, and annual kWh similarity.

What checks come before ordering KOHLER 34455 replacement parts?

Decode the serial manufacture year, verify active KOHLER CPSC recalls, and test the repair quote in the 50% estimator above.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)