Skip to main content
Ventilating Fans · Rank #400 of 900

S&P RF8-120 Ventilating Fan Specs

Spanning single SKU RF8-120EC, S&P RF8-120 logs Fan Efficacy 4.9 CFM/W inside a standard residential footprint built for 130.0 CFM. Out of 900 certified U.S. ventilating fans, this In-line (single-port) model achieves upper-half efficiency: #400 / 900 — tied with 12 peers, scores higher efficiency than 54.2% of 900 ventilating fans. Out-of-warranty owners weighing component quotes face rated service expectations across a 15-year NAHB lifespan and ENERGY STAR certified compliance under 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#400 of 900
Capacity
130.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #400 / 900 (tied with 12 at 4.9 CFM/W)
vs Ventilating Fans Median +0.3 CFM/W (+6.5%) EPA certified comparison
Federal Metric (Fan Efficacy) 4.9 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for S&P RF8-120?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

S&P RF8-120 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric RF8-120 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 130.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2018 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.9 CFM/W In-line (single-port) 6 inch diameter

Which ventilating fans match RF8-120 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs RF8-120 Capacity Cutout Dimensions SKUs
Tech Drive TD-BF-23L-5CCT(BL) Bathroom/Utility Room Not listed Not listed 130.0 CFM Not listed 1
Air King F130D In-line (single-port) Not listed Not listed 130.0 CFM Not listed 1
Air King QFAMD In-line (single-port) Not listed Not listed 130.0 CFM Not listed 1
Dayton 3DPE5 Bathroom/Utility Room Not listed Not listed 130.0 CFM Not listed 1
Whirlpool Corporation WVW73UC0L Range Hood Not listed Not listed 132.2 CFM Not listed 1

Does RF8-120 carry R-600a, duct, or installation boundaries?

RF8-120 (In-line (single-port), 4.9 CFM/W) vents humid indoor air outdoors via 6 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • RF8-120EC

Should you repair RF8-120 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What is the projected 15-year power cost for S&P RF8-120?

Multiplying certified ENERGY STAR status by the U.S. EIA residential average of 18.16 cents/kWh places S&P RF8-120 running cost at scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) over its 15-year NAHB component life.

Does S&P RF8-120 outperform the ventilating fans category median?

Against a category median of 0.0 kWh/yr across 900 chassis, S&P RF8-120 stands at rank #400: +0.3 CFM/W (+6.5%); Rank #400 / 900 (tied with 12 at 4.9 CFM/W).

What is the 50% cost threshold for S&P RF8-120 repairs?

Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 7.5 years.

Which installations do NOT fit S&P RF8-120?

Skip S&P RF8-120 if your cabinet cutout cannot fit OEM cutout blueprint, if 130.0 CFM cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.

Why are 1 SKU variants grouped under S&P RF8-120?

Manufacturers file separate paint letters such as RF8-120EC for one mechanical chassis; grouping them shows true certified ENERGY STAR status and 130.0 CFM specs without duplicate model clutter.

Which hazards forbid uncertified work on S&P RF8-120?

Always shut off the electrical breaker and water shutoff valve before opening RF8-120 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Can you swap S&P RF8-120 without modifying kitchen framing?

Inspect the 5 nearest peers matched to OEM cutout blueprint and 130.0 CFM; selecting a peer matching RF8-120's width avoids countertop or cabinet trim alterations.

Why screen recall notices for S&P RF8-120 before paid service?

Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)