Tech Drive FA-BF-04-L(BL) Ventilating Fan Specs
Verified EPA ENERGY STAR test logs for Tech Drive FA-BF-04-L(BL) list Fan Efficacy 4.5 CFM/W and 110.0 CFM, giving this higher-draw Bathroom/Utility Room unit clear cost separation at -0.1 CFM/W (-2.2%) relative to the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU FA-BF-04-L(BL). Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #491 of 900
- Capacity
- 110.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Tech Drive FA-BF-04-L(BL)?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | FA-BF-04-L(BL) Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 110.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2026 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 4.5 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |
Which ventilating fans match FA-BF-04-L(BL) in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs FA-BF-04-L(BL) | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| AERO PURE ABF110G15 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Air King E80S | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Air King E80SH | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| AUPU AV11A1 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| AUPU AV11A2 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
Does FA-BF-04-L(BL) carry R-600a, duct, or installation boundaries?
FA-BF-04-L(BL) (Bathroom/Utility Room, 4.5 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- FA-BF-04-L(BL)
Should you repair FA-BF-04-L(BL) or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running Tech Drive FA-BF-04-L(BL) cost each year?
At 18.16 cents/kWh (EIA August 2026), Tech Drive FA-BF-04-L(BL) draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically FA-BF-04-L(BL).
How efficient is Tech Drive FA-BF-04-L(BL) compared with federal ceilings?
Measured against 10 CFR 430 certified, Tech Drive FA-BF-04-L(BL) holds rank #491 out of 900 U.S. ENERGY STAR ventilating fans: -0.1 CFM/W (-2.2%) vs median 0.0 kWh/yr.
Which minor parts are exceptions to replacing Tech Drive FA-BF-04-L(BL)?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is Tech Drive FA-BF-04-L(BL) a poor match for a remodel?
Avoid Tech Drive FA-BF-04-L(BL) if 110.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the Tech Drive FA-BF-04-L(BL) line use identical energy?
Yes; every listed finish — including FA-BF-04-L(BL) — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 110.0 CFM volume.
What safety codes restrict Tech Drive FA-BF-04-L(BL) disassembly?
Always shut off the electrical breaker and water shutoff valve before opening FA-BF-04-L(BL) service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for Tech Drive FA-BF-04-L(BL)?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on Tech Drive FA-BF-04-L(BL)?
Inspect the inner liner wall, door rim, or tub flange via the Tech Drive serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)