Tech Drive TD-BF-11 Ventilating Fan Specs
Verified EPA ENERGY STAR test logs for Tech Drive TD-BF-11 list Fan Efficacy 4 CFM/W and 90.0 CFM, giving this higher-draw Bathroom/Utility Room unit clear cost separation at -0.6 CFM/W (-13.0%) relative to the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU TD-BF-11. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #663 of 900
- Capacity
- 90.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Tech Drive TD-BF-11?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | TD-BF-11 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 90.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2024 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 4.0 CFM/W | Bathroom/Utility Room | 4.00 inch diameter |
Which ventilating fans match TD-BF-11 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs TD-BF-11 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Akicon AK1390N1-W/B/S | Bathroom/Utility Room | Not listed | Not listed | 90.0 CFM | Not listed | 1 |
| Panasonic FV-0709VBL1 | Bathroom/Utility Room | Not listed | Not listed | 90.0 CFM | Not listed | 1 |
| Panasonic RG-M79L | Bathroom/Utility Room | Not listed | Not listed | 90.0 CFM | Not listed | 1 |
| Akicon AK1390N2- | Bathroom/Utility Room | Not listed | Not listed | 90.0 CFM | Not listed | 3 |
| Akicon AK1390N3-W/B/S | Bathroom/Utility Room | Not listed | Not listed | 90.0 CFM | Not listed | 1 |
Does TD-BF-11 carry R-600a, duct, or installation boundaries?
TD-BF-11 (Bathroom/Utility Room, 4.0 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- TD-BF-11
Should you repair TD-BF-11 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What does Tech Drive TD-BF-11 consume in kWh and dollars?
EPA data records certified ENERGY STAR status for Tech Drive TD-BF-11, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 1 consolidated SKU finishes.
How far below the federal ceiling is Tech Drive TD-BF-11?
It posts 10 CFR 430 certified and places #663 of 900 ventilating fans: -0.6 CFM/W (-13.0%) relative to the 0.0 kWh/yr median.
At what age does Tech Drive TD-BF-11 fail the 50% repair test?
Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.
Which buyers should skip Tech Drive TD-BF-11?
Skip TD-BF-11 if cabinet openings cannot clear OEM cutout blueprint, if 90.0 CFM misses family sizing, or if commercial heavy-use durability is required.
Are TD-BF-11 mechanically the same model?
Yes; cosmetic finish trims (1 total SKUs) share identical certified ENERGY STAR status efficiency, 90.0 CFM interior rating, and chassis assemblies.
Which safety boundaries restrict Tech Drive TD-BF-11 DIY work?
Always shut off the electrical breaker and water shutoff valve before opening TD-BF-11 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
Which peer alternatives match Tech Drive TD-BF-11?
Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 90.0 CFM capacity, and annual kWh similarity.
What checks come before ordering Tech Drive TD-BF-11 replacement parts?
Decode the serial manufacture year, verify active Tech Drive CPSC recalls, and test the repair quote in the 50% estimator above.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)