Skip to main content
Water Heaters · Rank #1,105 of 1,114

American VG8275T100*V Water Heater Specs

Designed for a 24-inch compact alcove at 74.0 gal, American VG8275T100*V draws UEF 0.86 UEF and ranks -2.1 UEF (-71.3%) relative to the 3 UEF median among 1,169 certified water heaters. Factory color variants map back to single SKU VG8275T100*V. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to rated service expectations across a 10-year NAHB lifespan.

Rated Energy
Water Heaters
EIA Annual Cost
Not listed
Category Rank
#1,105 of 1,114
Capacity
74.0 gal
NAHB Lifespan
10 years
Annual Energy Draw Certified Rank #1,105 / 1,114 (tied for lowest rank)
vs Water Heaters Median -2.1 UEF (-71.3%) Median 1,082.0 kWh/yr
Federal Metric (UEF) 0.86 UEF 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

How does VG8275T100*V compare across all 1,114 water heaters?

American VG8275T100*V (unrated annual kWh) sits against the water heaters category median of 1,082.0 kWh/yr, -2.1 UEF (-71.3%), and U.S. 10 CFR 430 baselines.

VG8275T100*V vs Water Heaters Energy Distribution Chart of 582 water heaters from 643 to 1741 kWh/yr; median is 1082 kWh/yr. 643-721 kWh/yr: 9 models 721-800 kWh/yr: 12 models 800-878 kWh/yr: 106 models 878-957 kWh/yr: 132 models 957-1035 kWh/yr: 20 models 1035-1114 kWh/yr: 16 models 1114-1192 kWh/yr: 32 models 1192-1270 kWh/yr: 88 models 1270-1349 kWh/yr: 85 models 1349-1427 kWh/yr: 59 models 1427-1506 kWh/yr: 4 models 1506-1584 kWh/yr: 12 models 1584-1663 kWh/yr: 6 models 1663-1741 kWh/yr: 1 modelsMedian 1082 643 kWh/yrWater Heaters annual energy spread (n=582)1741 kWh/yr
View quantile summary for Water Heaters — VG8275T100*V
Quantile / MarkerAnnual kWh/yr
Most efficient model643 kWh/yr kWh
25th percentile883 kWh/yr kWh
Category median1082 kWh/yr kWh
75th percentile1289 kWh/yr kWh
Highest rated draw1741 kWh/yr kWh

What are the official specs and computed benchmarks for American VG8275T100*V?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.

American VG8275T100*V — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric VG8275T100*V Value Category / Federal Benchmark Computed Insight & Formula
Capacity 74.0 gal [U.S. Environmental Protection Agency (ENERGY STAR)] Standard gal rating Density unavailable
Cutout W × H × D 22.5" W × 51.9" H [U.S. Environmental Protection Agency (ENERGY STAR)] Released 2025 Single model listing (1 SKU)
NAHB Service Life 10 years [National Association of Home Builders (NAHB)] 50% age gate: 5.0 yrs Evaluate repair vs net replacement once age passes 6.5 yrs
UEF 0.86 UEF Natural Gas, Propane Power Vent

Which water heaters match VG8275T100*V in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Water Heaters (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs VG8275T100*V Capacity Cutout Dimensions SKUs
A. O. Smith GDHE-75 3 Gas-fired Storage Residential-duty Commercial Not listed Not listed 74.0 gal 22.5" W × 51.9" H 1
A. O. Smith HDHE-75 4 Gas-fired Storage Residential-duty Commercial Not listed Not listed 74.0 gal 22.5" W × 51.9" H 1
GSW WATER HEATERS 6G75100*PDVH0* 3 Gas-fired Storage Residential-duty Commercial Not listed Not listed 74.0 gal 22.5" W × 51.9" H 1
GSW WATER HEATERS 8G-75100*PDV-H06* 4 Gas-fired Storage Residential-duty Commercial Not listed Not listed 74.0 gal 22.5" W × 51.9" H 1
RELIANCE WATER HEATERS 6-75- *TPDT 3 Gas-fired Storage Residential-duty Commercial Not listed Not listed 74.0 gal 22.5" W × 51.9" H 1

Does VG8275T100*V carry R-600a, duct, or installation boundaries?

VG8275T100*V (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane, UEF 0.86) supplies residential hot water; heat-pump models need ~700 cu ft surrounding air volume.

Verify T&P relief valve discharge piping, thermal expansion tanks, and 240V/gas connections with a licensed plumber or electrician; check $1,750 DOE HEAR heat-pump credits.

  • VG8275T100*V

Should you repair VG8275T100*V or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How much does running American VG8275T100*V cost each year?

At 18.16 cents/kWh (EIA August 2026), American VG8275T100*V draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically VG8275T100*V.

How efficient is American VG8275T100*V compared with federal ceilings?

Measured against 10 CFR 430 certified, American VG8275T100*V holds rank #1,105 out of 1,114 U.S. ENERGY STAR water heaters: -2.1 UEF (-71.3%) vs median 1082.0 kWh/yr.

Which minor parts are exceptions to replacing American VG8275T100*V?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 5.0 years, whereas motor or board quotes above 50% net replacement favor replacement.

When is American VG8275T100*V a poor match for a remodel?

Avoid American VG8275T100*V if 74.0 gal falls short of household demand, if hookups conflict with 22.5" W × 51.9" H, or if local electricity tariffs justify the lowest-kWh quartile.

Do all variants in the American VG8275T100*V line use identical energy?

Yes; every listed finish — including VG8275T100*V — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 74.0 gal volume.

What safety codes restrict American VG8275T100*V disassembly?

Always shut off the electrical breaker and water shutoff valve before opening VG8275T100*V service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

How should owners confirm cutout clearance for American VG8275T100*V?

Verify width, height, and depth against 22.5" W × 51.9" H, leaving extra rear space for cords, hoses, or condenser airflow.

Where is the serial tag located on American VG8275T100*V?

Inspect the inner liner wall, door rim, or tub flange via the American serial guide to decode build month and year before buying replacement assemblies.

Related guides

Sources

  1. ENERGY STAR Certified Residential Water Heaters Dataset (pbpq-swnu) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)