Richmond 10E65-HP120 Water Heater Specs
Designed for a 28-inch apartment alcove at 59.0 gal, Richmond 10E65-HP120 draws 971 kWh/yr ($176.33/yr at 18.16c/kWh) and ranks -111 kWh/yr (-10.3%) relative to the 1,082 kWh/yr median among 1,169 certified water heaters. Factory color variants map back to 2 finish SKUs including 10E65-HP120M, 10E65-HP120MS. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to $1,763.30 over a 10-year NAHB lifespan.
- Rated Energy
- 971 kWh/yr
- EIA Annual Cost
- $176.33/yr
- Category Rank
- #265 of 582
- Capacity
- 59.0 gal
- NAHB Lifespan
- 10 years
How does 10E65-HP120 compare across all 582 water heaters?
Richmond 10E65-HP120 (971 kWh/yr) sits against the water heaters category median of 1,082.0 kWh/yr, -111 kWh/yr (-10.3%), and U.S. 10 CFR 430 baselines.
View quantile summary for Water Heaters — 10E65-HP120
| Quantile / Marker | Annual kWh/yr |
|---|---|
| Most efficient model | 643 kWh/yr kWh |
| 25th percentile | 883 kWh/yr kWh |
| Category median | 1082 kWh/yr kWh |
| 75th percentile | 1289 kWh/yr kWh |
| Highest rated draw | 1741 kWh/yr kWh |
Where does 10E65-HP120 rank in operating-cost percentile?
Ranked #265 of 582 rated water heaters using EIA August 2026 national residential electricity rates (18.16 cents/kWh) over a 10-year NAHB median lifespan.
What are the official specs and computed benchmarks for Richmond 10E65-HP120?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (10 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | 10E65-HP120 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Rated Energy | 971 kWh/yr [U.S. Environmental Protection Agency (ENERGY STAR)] | Median 1,082 kWh/yr | Rank #265 of 582 water heaters (tied with 8 peers) (-111 kWh/yr, -10.3% vs median) |
| Capacity | 59.0 gal [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard gal rating | 16.46 kWh/gal (-13.6% vs 19.06 median) |
| Cutout W × H × D | 24.3" W × 64.2" H [U.S. Environmental Protection Agency (ENERGY STAR)] | Released 2022 | Consolidates 2 finish variants |
| Operating Cost (EIA) | $176.33/yr [U.S. Energy Information Administration (EIA)] | 18.16 c/kWh US avg | Formula: 971 kWh × $0.1816 = $176.33/yr ($1,763.30 over 10 yrs) |
| NAHB Service Life | 10 years [National Association of Home Builders (NAHB)] | 50% age gate: 5.0 yrs | Evaluate repair vs net replacement once age passes 6.5 yrs |
| UEF | 3.12 UEF | Electric | Certified efficiency metric |
Which water heaters match 10E65-HP120 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs 10E65-HP120 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Rheem PROPH65 T0 RH120-M | Hybrid/Electric Heat Pump | 971 | Same kWh | 59.0 gal | 24.3" W × 64.2" H | 1 |
| Rheem PROPH65 T0 RH120-MSO | Hybrid/Electric Heat Pump | 971 | Same kWh | 59.0 gal | 24.3" W × 64.2" H | 1 |
| Rheem XE65T10HM00U0 | Hybrid/Electric Heat Pump | 971 | Same kWh | 59.0 gal | 24.3" W × 64.2" H | 1 |
| Rheem XE65T10HMS00U0 | Hybrid/Electric Heat Pump | 971 | Same kWh | 59.0 gal | 24.3" W × 64.2" H | 1 |
| Ruud PROUH65 T0 RU120-M | Hybrid/Electric Heat Pump | 971 | Same kWh | 59.0 gal | 24.3" W × 64.2" H | 1 |
Does 10E65-HP120 carry R-600a, duct, or installation boundaries?
10E65-HP120 (Hybrid/Electric Heat Pump, Electric, UEF 3.12) supplies residential hot water; heat-pump models need ~700 cu ft surrounding air volume.
Verify T&P relief valve discharge piping, thermal expansion tanks, and 240V/gas connections with a licensed plumber or electrician; check $1,750 DOE HEAR heat-pump credits.
- 10E65-HP120M
- 10E65-HP120MS
Should you repair 10E65-HP120 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much electricity does the Richmond 10E65-HP120 draw each year?
EPA ENERGY STAR lists Richmond 10E65-HP120 at 971 kWh/yr, producing an estimated utility outlay of $176.33/yr ($1,763 over 10 years) at the U.S. EIA residential benchmark of 18.16 cents/kWh across 2 finish SKUs.
How does Richmond 10E65-HP120 compare against the federal limit?
Against the 10 CFR 430 certified, this Richmond water heater ranks #265 among 582 certified water heaters — -111 kWh/yr (-10.3%) vs the 1082.0 kWh/yr median.
When is repairing Richmond 10E65-HP120 out of warranty NOT worthwhile?
Avoid major mechanical or control-board repairs once Richmond 10E65-HP120 passes 5.0 years (half its 10-year NAHB lifespan) or whenever a technician quote reaches 50% of net replacement cost.
Who should NOT install the Richmond 10E65-HP120 water heater?
Do not specify Richmond 10E65-HP120 (59.0 gal) for commercial duty cycles, tight alcoves that cannot clear 24.3" W × 64.2" H plus ventilation gaps, or inside an active year-1 manufacturer warranty period.
Which SKU trims map to the Richmond 10E65-HP120 appliance models?
CodeBench merges 2 finish codes, led by 10E65-HP120M, 10E65-HP120MS, under 10E65-HP120 because color suffixes share identical core power draw, 59.0 gal volume, and outer cabinet dimensions.
What safety rules govern Richmond 10E65-HP120 repairs?
Always shut off the electrical breaker and water shutoff valve before opening 10E65-HP120 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How do 5 peer alternatives match up to Richmond 10E65-HP120?
The peer table compares 5 water heaters selected closest to 10E65-HP120 by cutout width, 59.0 gal capacity, and 971 kWh/yr rating so homeowners can evaluate direct drop-in replacements.
How do you verify the build age of Richmond 10E65-HP120?
Check the interior serial sticker with the Richmond serial date guide rather than relying only on the 2022 catalog release year, especially when 10-year codes repeat.
Related guides
Sources
- ENERGY STAR Certified Residential Water Heaters Dataset (pbpq-swnu) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)