Skip to main content
Ventilating Fans · Rank #449 of 900

Air King EVLDH Ventilating Fan Specs

Verified EPA ENERGY STAR test logs for Air King EVLDH list Fan Efficacy 4.6 CFM/W and 150.0 CFM, giving this higher-draw Bathroom/Utility Room unit clear cost separation at matching the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU EVLDH. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#449 of 900
Capacity
150.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Tied with 41 peers at 4.6 CFM/W (median)
vs Ventilating Fans Median Equal to median EPA certified comparison
Federal Metric (Fan Efficacy) 4.6 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Air King EVLDH?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Air King EVLDH — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric EVLDH Value Category / Federal Benchmark Computed Insight & Formula
Capacity 150.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2017 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.6 CFM/W Bathroom/Utility Room 6 inch diameter

Which ventilating fans match EVLDH in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs EVLDH Capacity Cutout Dimensions SKUs
ACIQ AEP150 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 1
Anzzi EF-AZ104 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 1
Anzzi EF-AZ105 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 1
Broan ALT1303 Range Hood Not listed Not listed 150.0 CFM Not listed 2
Broan ALT2303 Range Hood Not listed Not listed 150.0 CFM Not listed 1

Does EVLDH carry R-600a, duct, or installation boundaries?

EVLDH (Bathroom/Utility Room, 4.6 CFM/W) vents humid indoor air outdoors via 6 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • EVLDH

Should you repair EVLDH or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What annual electricity outlay should Air King EVLDH owners budget?

Rated at certified ENERGY STAR status, Air King EVLDH averages scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) under EIA's 18.16 cents/kWh U.S. average over 15 years of NAHB service life.

Where does Air King EVLDH sit among 900 certified peers?

Out of 900 U.S. certified ventilating fans, Air King EVLDH ranks #449 — Tied with 41 peers at 4.6 CFM/W (median) — against 10 CFR 430 certified.

Should owners repair a failing Air King EVLDH past 15 years?

NAHB places median ventilating fan service life at 15 years; past 7.5 years, estimates exceeding 50% of net new price (after $150 5-yr savings) favor replacement.

Who is Air King EVLDH NOT designed for?

Commercial establishments, alcoves smaller than OEM cutout blueprint, and households requiring different capacity than 150.0 CFM should review peer alternatives above.

Which model numbers belong to the Air King EVLDH platform?

All 1 finish code maps to the identical EVLDH platform, notably EVLDH: certified ENERGY STAR status vs 0.0 kWh/yr category median.

What safety checks precede opening Air King EVLDH housings?

Always shut off the electrical breaker and water shutoff valve before opening EVLDH service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

How does Air King EVLDH fit standard residential cutouts?

Measuring OEM cutout blueprint at 150.0 CFM, EVLDH aligns closely with the 5 nearest peer ventilating fans ranked in the alternative table above.

Can you date Air King EVLDH if purchase paperwork is missing?

Yes; check the cabinet serial tag in our Air King serial decoder to confirm manufacture year and out-of-warranty status.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)