Skip to main content
Ventilating Fans · Rank #449 of 900

Anzzi EF-AZ105 Ventilating Fan Specs

Anzzi EF-AZ105 (Bathroom/Utility Room) places #449 of 900 certified U.S. ventilating fans with Fan Efficacy 4.6 CFM/W and 150.0 CFM. Sized for a standard residential footprint, this chassis consolidates single SKU EF-AZ105WH to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 15-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#449 of 900
Capacity
150.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Tied with 41 peers at 4.6 CFM/W (median)
vs Ventilating Fans Median Equal to median EPA certified comparison
Federal Metric (Fan Efficacy) 4.6 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Anzzi EF-AZ105?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Anzzi EF-AZ105 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric EF-AZ105 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 150.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2024 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.6 CFM/W Bathroom/Utility Room 6.00 inch depth X 0.00 inch width

Which ventilating fans match EF-AZ105 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs EF-AZ105 Capacity Cutout Dimensions SKUs
ACIQ AEP150 Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 1
Air King EVLD Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 1
Air King EVLDGH Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 1
Air King EVLDH Bathroom/Utility Room Not listed Not listed 150.0 CFM Not listed 1
Broan ALT1303 Range Hood Not listed Not listed 150.0 CFM Not listed 2

Does EF-AZ105 carry R-600a, duct, or installation boundaries?

EF-AZ105 (Bathroom/Utility Room, 4.6 CFM/W) vents humid indoor air outdoors via 6.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • EF-AZ105WH

Should you repair EF-AZ105 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What does Anzzi EF-AZ105 consume in kWh and dollars?

EPA data records certified ENERGY STAR status for Anzzi EF-AZ105, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 1 consolidated SKU finishes.

How far below the federal ceiling is Anzzi EF-AZ105?

It posts 10 CFR 430 certified and places #449 of 900 ventilating fans: Equal to median relative to the 0.0 kWh/yr median.

At what age does Anzzi EF-AZ105 fail the 50% repair test?

Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.

Which buyers should skip Anzzi EF-AZ105?

Skip EF-AZ105 if cabinet openings cannot clear OEM cutout blueprint, if 150.0 CFM misses family sizing, or if commercial heavy-use durability is required.

Are EF-AZ105WH mechanically the same model?

Yes; cosmetic finish trims (1 total SKUs) share identical certified ENERGY STAR status efficiency, 150.0 CFM interior rating, and chassis assemblies.

Which safety boundaries restrict Anzzi EF-AZ105 DIY work?

Always shut off the electrical breaker and water shutoff valve before opening EF-AZ105 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Which peer alternatives match Anzzi EF-AZ105?

Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 150.0 CFM capacity, and annual kWh similarity.

What checks come before ordering Anzzi EF-AZ105 replacement parts?

Decode the serial manufacture year, verify active Anzzi CPSC recalls, and test the repair quote in the 50% estimator above.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)