Broan GLA1423 Ventilating Fan Specs
Specified at 150.0 CFM and Fan Efficacy 4.6 CFM/W, Broan GLA1423 #449 / 900 — tied with 41 peers, scores higher efficiency than 45.6% of 900 ventilating fans in the U.S. ENERGY STAR directory. Shared internal engineering unites 2 finish SKUs including GLA1423SS, GLA1423WW within a standard residential footprint. Evaluated over a 15-year NAHB benchmark service window, operating power equals rated service expectations across a 15-year NAHB lifespan with ENERGY STAR certified margin under DOE 10 CFR 430.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #449 of 900
- Capacity
- 150.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Broan GLA1423?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | GLA1423 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 150.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2025 | 2 SKUs | Consolidates 2 finish variants |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 4.6 CFM/W | Range Hood | 7.00 inch depth X 0.00 inch width |
Which ventilating fans match GLA1423 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs GLA1423 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| ACIQ AEP150 | Bathroom/Utility Room | Not listed | Not listed | 150.0 CFM | Not listed | 1 |
| Air King EVLD | Bathroom/Utility Room | Not listed | Not listed | 150.0 CFM | Not listed | 1 |
| Air King EVLDGH | Bathroom/Utility Room | Not listed | Not listed | 150.0 CFM | Not listed | 1 |
| Air King EVLDH | Bathroom/Utility Room | Not listed | Not listed | 150.0 CFM | Not listed | 1 |
| Anzzi EF-AZ104 | Bathroom/Utility Room | Not listed | Not listed | 150.0 CFM | Not listed | 1 |
Does GLA1423 carry R-600a, duct, or installation boundaries?
GLA1423 (Range Hood, 4.6 CFM/W) vents humid indoor air outdoors via 7.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- GLA1423SS
- GLA1423WW
Should you repair GLA1423 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What does Broan GLA1423 consume in kWh and dollars?
EPA data records certified ENERGY STAR status for Broan GLA1423, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 2 consolidated SKU finishes.
How far below the federal ceiling is Broan GLA1423?
It posts 10 CFR 430 certified and places #449 of 900 ventilating fans: Equal to median relative to the 0.0 kWh/yr median.
At what age does Broan GLA1423 fail the 50% repair test?
Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.
Which buyers should skip Broan GLA1423?
Skip GLA1423 if cabinet openings cannot clear OEM cutout blueprint, if 150.0 CFM misses family sizing, or if commercial heavy-use durability is required.
Are GLA1423SS, GLA1423WW mechanically the same model?
Yes; cosmetic finish trims (2 total SKUs) share identical certified ENERGY STAR status efficiency, 150.0 CFM interior rating, and chassis assemblies.
Which safety boundaries restrict Broan GLA1423 DIY work?
Always shut off the electrical breaker and water shutoff valve before opening GLA1423 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
Which peer alternatives match Broan GLA1423?
Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 150.0 CFM capacity, and annual kWh similarity.
What checks come before ordering Broan GLA1423 replacement parts?
Decode the serial manufacture year, verify active Broan CPSC recalls, and test the repair quote in the 50% estimator above.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)