Skip to main content
Ventilating Fans · Rank #376 of 900

Anzzi EF-AZ101 Ventilating Fan Specs

Specified at 80.0 CFM and Fan Efficacy 5.3 CFM/W, Anzzi EF-AZ101 scores higher efficiency than 57.9% of 900 ventilating fans in the U.S. ENERGY STAR directory. Shared internal engineering unites single SKU EF-AZ101WH within a standard residential footprint. Evaluated over a 15-year NAHB benchmark service window, operating power equals rated service expectations across a 15-year NAHB lifespan with ENERGY STAR certified margin under DOE 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#376 of 900
Capacity
80.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #376 / 900 (top 42.1%)
vs Ventilating Fans Median +0.7 CFM/W (+15.2%) EPA certified comparison
Federal Metric (Fan Efficacy) 5.3 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Anzzi EF-AZ101?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Anzzi EF-AZ101 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric EF-AZ101 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 80.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2024 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 5.3 CFM/W Bathroom/Utility Room 4.00 inch depth X 0.00 inch width

Which ventilating fans match EF-AZ101 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs EF-AZ101 Capacity Cutout Dimensions SKUs
Haier QVE801DT Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1
Fantech RCS80L Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1
Fantech SMPL80 (484300) Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1
Fantech SMPL80L (484301) Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1
ACIQ ANP80 Bathroom/Utility Room Not listed Not listed 80.0 CFM Not listed 1

Does EF-AZ101 carry R-600a, duct, or installation boundaries?

EF-AZ101 (Bathroom/Utility Room, 5.3 CFM/W) vents humid indoor air outdoors via 4.00 inch depth X 0.00 inch width (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • EF-AZ101WH

Should you repair EF-AZ101 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What is the projected 15-year power cost for Anzzi EF-AZ101?

Multiplying certified ENERGY STAR status by the U.S. EIA residential average of 18.16 cents/kWh places Anzzi EF-AZ101 running cost at scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) over its 15-year NAHB component life.

Does Anzzi EF-AZ101 outperform the ventilating fans category median?

Against a category median of 0.0 kWh/yr across 900 chassis, Anzzi EF-AZ101 stands at rank #376: +0.7 CFM/W (+15.2%); Rank #376 / 900 (top 42.1%).

What is the 50% cost threshold for Anzzi EF-AZ101 repairs?

Subtract eligible incentives and 5-year energy savings ($150) from replacement retail price, then cap repair quotes at 50% once age exceeds 7.5 years.

Which installations do NOT fit Anzzi EF-AZ101?

Skip Anzzi EF-AZ101 if your cabinet cutout cannot fit OEM cutout blueprint, if 80.0 CFM cannot clear household doorways, or if commercial throughput exceeds residential engineering limits.

Why are 1 SKU variants grouped under Anzzi EF-AZ101?

Manufacturers file separate paint letters such as EF-AZ101WH for one mechanical chassis; grouping them shows true certified ENERGY STAR status and 80.0 CFM specs without duplicate model clutter.

Which hazards forbid uncertified work on Anzzi EF-AZ101?

Always shut off the electrical breaker and water shutoff valve before opening EF-AZ101 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Can you swap Anzzi EF-AZ101 without modifying kitchen framing?

Inspect the 5 nearest peers matched to OEM cutout blueprint and 80.0 CFM; selecting a peer matching EF-AZ101's width avoids countertop or cabinet trim alterations.

Why screen recall notices for Anzzi EF-AZ101 before paid service?

Active CPSC safety notices entitle owners to no-charge OEM remedies; always verify your exact serial number on CPSC recall bulletins before booking out-of-warranty work.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)