Skip to main content
Ventilating Fans · Rank #529 of 900

Aprilaire 8145 Ventilating Fan Specs

Verified EPA ENERGY STAR test logs for Aprilaire 8145 list Fan Efficacy 4.4 CFM/W and 190.0 CFM, giving this higher-draw In-line (single-port) unit clear cost separation at -0.2 CFM/W (-4.3%) relative to the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU 8145. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#529 of 900
Capacity
190.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #529 / 900 (tied with 32 at 4.4 CFM/W)
vs Ventilating Fans Median -0.2 CFM/W (-4.3%) EPA certified comparison
Federal Metric (Fan Efficacy) 4.4 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Aprilaire 8145?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Aprilaire 8145 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric 8145 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 190.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2020 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 4.4 CFM/W In-line (single-port) 6.00 inch diameter

Which ventilating fans match 8145 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs 8145 Capacity Cutout Dimensions SKUs
Panasonic FV-20VQ3 Bathroom/Utility Room Not listed Not listed 190.0 CFM Not listed 1
Aprilaire 8145NC In-line (multi-port) Not listed Not listed 190.0 CFM Not listed 1
Broan L150EL In-line (single-port) Not listed Not listed 170.0 CFM Not listed 1
Dayton 5AE71 Bathroom/Utility Room Not listed Not listed 210.0 CFM Not listed 1
Commercial Electric BF1115 Bathroom/Utility Room Not listed Not listed 160.0 CFM Not listed 1

Does 8145 carry R-600a, duct, or installation boundaries?

8145 (In-line (single-port), 4.4 CFM/W) vents humid indoor air outdoors via 6.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • 8145

Should you repair 8145 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

What does Aprilaire 8145 consume in kWh and dollars?

EPA data records certified ENERGY STAR status for Aprilaire 8145, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 1 consolidated SKU finishes.

How far below the federal ceiling is Aprilaire 8145?

It posts 10 CFR 430 certified and places #529 of 900 ventilating fans: -0.2 CFM/W (-4.3%) relative to the 0.0 kWh/yr median.

At what age does Aprilaire 8145 fail the 50% repair test?

Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.

Which buyers should skip Aprilaire 8145?

Skip 8145 if cabinet openings cannot clear OEM cutout blueprint, if 190.0 CFM misses family sizing, or if commercial heavy-use durability is required.

Are 8145 mechanically the same model?

Yes; cosmetic finish trims (1 total SKUs) share identical certified ENERGY STAR status efficiency, 190.0 CFM interior rating, and chassis assemblies.

Which safety boundaries restrict Aprilaire 8145 DIY work?

Always shut off the electrical breaker and water shutoff valve before opening 8145 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

Which peer alternatives match Aprilaire 8145?

Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 190.0 CFM capacity, and annual kWh similarity.

What checks come before ordering Aprilaire 8145 replacement parts?

Decode the serial manufacture year, verify active Aprilaire CPSC recalls, and test the repair quote in the 50% estimator above.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)