AUPU AV11AL2 Ventilating Fan Specs
AUPU AV11AL2 (Bathroom/Utility Room) places #529 of 900 certified U.S. ventilating fans with Fan Efficacy 4.4 CFM/W and 110.0 CFM. Sized for a standard residential footprint, this chassis consolidates single SKU AV11AL2 to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 15-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #529 of 900
- Capacity
- 110.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for AUPU AV11AL2?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | AV11AL2 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 110.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2018 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 4.4 CFM/W | Bathroom/Utility Room | 4 inch diameter |
Which ventilating fans match AV11AL2 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs AV11AL2 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| AERO PURE ABF110G16 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| AERO PURE ABF110L5 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| AERO PURE ABF110L6 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Amazon Basics B089R8S365 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| HomeWerks Worldwide 7141-110-G4 | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
Does AV11AL2 carry R-600a, duct, or installation boundaries?
AV11AL2 (Bathroom/Utility Room, 4.4 CFM/W) vents humid indoor air outdoors via 4 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- AV11AL2
Should you repair AV11AL2 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running AUPU AV11AL2 cost each year?
At 18.16 cents/kWh (EIA August 2026), AUPU AV11AL2 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically AV11AL2.
How efficient is AUPU AV11AL2 compared with federal ceilings?
Measured against 10 CFR 430 certified, AUPU AV11AL2 holds rank #529 out of 900 U.S. ENERGY STAR ventilating fans: -0.2 CFM/W (-4.3%) vs median 0.0 kWh/yr.
Which minor parts are exceptions to replacing AUPU AV11AL2?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is AUPU AV11AL2 a poor match for a remodel?
Avoid AUPU AV11AL2 if 110.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the AUPU AV11AL2 line use identical energy?
Yes; every listed finish — including AV11AL2 — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 110.0 CFM volume.
What safety codes restrict AUPU AV11AL2 disassembly?
Always shut off the electrical breaker and water shutoff valve before opening AV11AL2 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for AUPU AV11AL2?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on AUPU AV11AL2?
Inspect the inner liner wall, door rim, or tub flange via the AUPU serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)