Delta ITG50L Ventilating Fan Specs
Designed for a standard residential footprint at 50.0 CFM, Delta ITG50L draws Fan Efficacy 10.8 CFM/W and ranks +6.2 CFM/W (+134.8%) relative to the 4.6 CFM/W median among 900 certified ventilating fans. Factory color variants map back to single SKU ITG50LED. Pairing ENERGY STAR certified DOE 10 CFR 430 compliance with NAHB median expectancy points to rated service expectations across a 15-year NAHB lifespan.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #116 of 900
- Capacity
- 50.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Delta ITG50L?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | ITG50L Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 50.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2016 | 1 SKU | Single model listing (1 SKU) |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 10.8 CFM/W | Bathroom/Utility Room | 4 inch diameter |
Which ventilating fans match ITG50L in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs ITG50L | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Hampton Bay 7114-02 | Bathroom/Utility Room | Not listed | Not listed | 50.0 CFM | Not listed | 1 |
| HomeWerks Worldwide 7114-02- | Bathroom/Utility Room | Not listed | Not listed | 50.0 CFM | Not listed | 1 |
| Utilitech 7114-02-L | Bathroom/Utility Room | Not listed | Not listed | 50.0 CFM | Not listed | 1 |
| Broan XB50 | Bathroom/Utility Room | Not listed | Not listed | 50.0 CFM | Not listed | 2 |
| Broan XB50=XB00HWITHXB50F | Bathroom/Utility Room | Not listed | Not listed | 50.0 CFM | Not listed | 2 |
Does ITG50L carry R-600a, duct, or installation boundaries?
ITG50L (Bathroom/Utility Room, 10.8 CFM/W) vents humid indoor air outdoors via 4 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- ITG50LED
Should you repair ITG50L or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
How much does running Delta ITG50L cost each year?
At 18.16 cents/kWh (EIA August 2026), Delta ITG50L draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically ITG50LED.
How efficient is Delta ITG50L compared with federal ceilings?
Measured against 10 CFR 430 certified, Delta ITG50L holds rank #116 out of 900 U.S. ENERGY STAR ventilating fans: +6.2 CFM/W (+134.8%) vs median 0.0 kWh/yr.
Which minor parts are exceptions to replacing Delta ITG50L?
Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.
When is Delta ITG50L a poor match for a remodel?
Avoid Delta ITG50L if 50.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.
Do all variants in the Delta ITG50L line use identical energy?
Yes; every listed finish — including ITG50LED — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 50.0 CFM volume.
What safety codes restrict Delta ITG50L disassembly?
Always shut off the electrical breaker and water shutoff valve before opening ITG50L service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
How should owners confirm cutout clearance for Delta ITG50L?
Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.
Where is the serial tag located on Delta ITG50L?
Inspect the inner liner wall, door rim, or tub flange via the Delta serial guide to decode build month and year before buying replacement assemblies.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)