Panasonic RG-R811 Ventilating Fan Specs
Panasonic RG-R811 (Bathroom/Utility Room) places #340 of 900 certified U.S. ventilating fans with Fan Efficacy 6.1 CFM/W and 110.0 CFM. Sized for a standard residential footprint, this chassis consolidates 4 finish SKUs including RG-R811A, RG-R811HA to prevent duplicate parts lookup. Projected electricity totals rated service expectations across a 15-year NAHB lifespan at August 2026 EIA rates, keeping ENERGY STAR certified headroom under federal 10 CFR 430 rules.
- Rated Energy
- Ventilating Fans
- EIA Annual Cost
- Not listed
- Category Rank
- #340 of 900
- Capacity
- 110.0 CFM
- NAHB Lifespan
- 15 years
What are the official specs and computed benchmarks for Panasonic RG-R811?
Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.
| Specification / Metric | RG-R811 Value | Category / Federal Benchmark | Computed Insight & Formula |
|---|---|---|---|
| Capacity | 110.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] | Standard CFM rating | Density unavailable |
| Listing & Release | Released 2022 | 4 SKUs | Consolidates 4 finish variants |
| NAHB Service Life | 15 years [National Association of Home Builders (NAHB)] | 50% age gate: 7.5 yrs | Evaluate repair vs net replacement once age passes 9.8 yrs |
| Fan Efficacy | 6.1 CFM/W | Bathroom/Utility Room | 3.00 inch diameter |
Which ventilating fans match RG-R811 in cutout width and energy draw?
Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.
| Peer Model | Subtype | kWh/yr | Delta vs RG-R811 | Capacity | Cutout Dimensions | SKUs |
|---|---|---|---|---|---|---|
| Panasonic Eco Solutions RG-N110L | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 2 |
| RadonAway RP140 | In-line (single-port) | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Delta SLM50-110LED- | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Delta SLM80-110DL | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
| Delta SLM80-110DLED- | Bathroom/Utility Room | Not listed | Not listed | 110.0 CFM | Not listed | 1 |
Does RG-R811 carry R-600a, duct, or installation boundaries?
RG-R811 (Bathroom/Utility Room, 6.1 CFM/W) vents humid indoor air outdoors via 3.00 inch diameter (never terminate into an enclosed attic).
Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.
- RG-R811A
- RG-R811HA
Should you repair RG-R811 or replace it under the 50% rule?
Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.
Which CPSC safety recalls match Panasonic equipment?
Active U.S. Consumer Product Safety Commission notices mentioning Panasonic; verify serial eligibility on CPSC.gov before paying out-of-warranty dispatch charges.
- 26618 (2026-07-16) — Panasonic Recalls Electric Toaster Ovens Due to Shock and Fire Hazards
FAQ
Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.
What does Panasonic RG-R811 consume in kWh and dollars?
EPA data records certified ENERGY STAR status for Panasonic RG-R811, costing scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) at 18.16 cents/kWh across 4 consolidated SKU finishes.
How far below the federal ceiling is Panasonic RG-R811?
It posts 10 CFR 430 certified and places #340 of 900 ventilating fans: +1.5 CFM/W (+32.6%) relative to the 0.0 kWh/yr median.
At what age does Panasonic RG-R811 fail the 50% repair test?
Past 7.5 years of the 15-year NAHB benchmark, repair bids above half of net replacement minus $150 energy savings generally favor buying new.
Which buyers should skip Panasonic RG-R811?
Skip RG-R811 if cabinet openings cannot clear OEM cutout blueprint, if 110.0 CFM misses family sizing, or if commercial heavy-use durability is required.
Are RG-R811A, RG-R811HA mechanically the same model?
Yes; cosmetic finish trims (4 total SKUs) share identical certified ENERGY STAR status efficiency, 110.0 CFM interior rating, and chassis assemblies.
Which safety boundaries restrict Panasonic RG-R811 DIY work?
Always shut off the electrical breaker and water shutoff valve before opening RG-R811 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.
Which peer alternatives match Panasonic RG-R811?
Review the 5 closest ventilating fans listed above, sorted by OEM cutout blueprint cutout, 110.0 CFM capacity, and annual kWh similarity.
What checks come before ordering Panasonic RG-R811 replacement parts?
Decode the serial manufacture year, verify active Panasonic CPSC recalls, and test the repair quote in the 50% estimator above.
Related guides
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
- Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)
- CPSC Recalls REST Web Services API (SaferProducts.gov) — U.S. Consumer Product Safety Commission (CPSC), REST JSON 2026 (retrieved 2026-11-23)