Skip to main content
Ventilating Fans · Rank #50 of 900

Utilitech UTS8090100 Ventilating Fan Specs

Verified EPA ENERGY STAR test logs for Utilitech UTS8090100 list Fan Efficacy 12.7 CFM/W and 100.0 CFM, giving this top-quartile efficiency Bathroom/Utility Room unit clear cost separation at +8.1 CFM/W (+176.1%) relative to the 4.6 CFM/W median. Built into a standard residential footprint, the assembly covers single SKU UTS8090100. Cumulative power cost runs rated service expectations across a 15-year NAHB lifespan while holding ENERGY STAR certified vs 10 CFR 430.

Rated Energy
Ventilating Fans
EIA Annual Cost
Not listed
Category Rank
#50 of 900
Capacity
100.0 CFM
NAHB Lifespan
15 years
Annual Energy Draw Certified Rank #50 / 900 (top 5.7%)
vs Ventilating Fans Median +8.1 CFM/W (+176.1%) EPA certified comparison
Federal Metric (Fan Efficacy) 12.7 CFM/W 10 CFR 430 certified
Est. Operating Cost Unrated Annual kWh not listed

What are the official specs and computed benchmarks for Utilitech UTS8090100?

Complete EPA ENERGY STAR ratings, 10 CFR 430 federal compliance ceilings, NAHB median service expectancy (15 years), and estimated operating electricity costs at 18.16 cents/kWh.

Utilitech UTS8090100 — Official Specs & Computed Benchmarks (EIA Rate: 18.16 cents/kWh)
Specification / Metric UTS8090100 Value Category / Federal Benchmark Computed Insight & Formula
Capacity 100.0 CFM [U.S. Environmental Protection Agency (ENERGY STAR)] Standard CFM rating Density unavailable
Listing & Release Released 2026 1 SKU Single model listing (1 SKU)
NAHB Service Life 15 years [National Association of Home Builders (NAHB)] 50% age gate: 7.5 yrs Evaluate repair vs net replacement once age passes 9.8 yrs
Fan Efficacy 12.7 CFM/W Bathroom/Utility Room 4.00 inch diameter

Which ventilating fans match UTS8090100 in cutout width and energy draw?

Five comparable U.S. ENERGY STAR base models matched closely on cabinet alcove width and annual energy draw so replacements clear existing cabinetry without electrical rework.

Nearest Peer Alternatives in Ventilating Fans (Matched by Width & kWh Draw)
Peer Model Subtype kWh/yr Delta vs UTS8090100 Capacity Cutout Dimensions SKUs
Revent RVS8090100 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1
Revent RVL8090100 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1
ACIQ ANPD100-3 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1
CFM TF100- Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 2
Broan LP50100 Bathroom/Utility Room Not listed Not listed 100.0 CFM Not listed 1

Does UTS8090100 carry R-600a, duct, or installation boundaries?

UTS8090100 (Bathroom/Utility Room, 12.7 CFM/W) vents humid indoor air outdoors via 4.00 inch diameter (never terminate into an enclosed attic).

Turn off dedicated lighting/fan breaker before removing grille cover or testing motor impedance.

  • UTS8090100

Should you repair UTS8090100 or replace it under the 50% rule?

Enter your appliance age, out-of-warranty quote, and replacement price to test the 50% NAHB threshold plus DOE HEAR ($840 cap) and EPA RAD ($25-$100) net rebates.

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How much does running Utilitech UTS8090100 cost each year?

At 18.16 cents/kWh (EIA August 2026), Utilitech UTS8090100 draws certified ENERGY STAR status, equating to scaled by local EIA tariffs (U.S. average 18.16 cents/kWh) across all 1 finish trim, specifically UTS8090100.

How efficient is Utilitech UTS8090100 compared with federal ceilings?

Measured against 10 CFR 430 certified, Utilitech UTS8090100 holds rank #50 out of 900 U.S. ENERGY STAR ventilating fans: +8.1 CFM/W (+176.1%) vs median 0.0 kWh/yr.

Which minor parts are exceptions to replacing Utilitech UTS8090100?

Routine wear items such as gaskets, lint filters, coin traps, or inlet mesh remain worthwhile past 7.5 years, whereas motor or board quotes above 50% net replacement favor replacement.

When is Utilitech UTS8090100 a poor match for a remodel?

Avoid Utilitech UTS8090100 if 100.0 CFM falls short of household demand, if hookups conflict with OEM cutout blueprint, or if local electricity tariffs justify the lowest-kWh quartile.

Do all variants in the Utilitech UTS8090100 line use identical energy?

Yes; every listed finish — including UTS8090100 — shares the identical certified ENERGY STAR status ENERGY STAR test rating and 100.0 CFM volume.

What safety codes restrict Utilitech UTS8090100 disassembly?

Always shut off the electrical breaker and water shutoff valve before opening UTS8090100 service panels, probing solenoid coils, or inspecting drain pumps and sump float switches.

How should owners confirm cutout clearance for Utilitech UTS8090100?

Verify width, height, and depth against OEM cutout blueprint, leaving extra rear space for cords, hoses, or condenser airflow.

Where is the serial tag located on Utilitech UTS8090100?

Inspect the inner liner wall, door rim, or tub flange via the Utilitech serial guide to decode build month and year before buying replacement assemblies.

Related guides

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. Environmental Protection Agency (ENERGY STAR), Socrata Open Data API 2026 (retrieved 2026-11-25)
  2. Study of Life Expectancy of Home Components — National Association of Home Builders (NAHB), NAHB Component Lifespan Benchmarks (retrieved 2026-11-23)
  3. Electric Power Monthly Table 5.6.A: Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), August 2026 & August 2025 (retrieved 2026-11-23)