Skip to main content
Residential Lock Standards

Schlage C Keyway (Ilco SC1 5-Pin / SC4 6-Pin)

Schlage C Keyway (Ilco SC1 5-Pin / SC4 6-Pin) uses 5-pin (SC1) / 6-pin (SC4) and a 0.015 in pin depth increment tolerance (ANSI/BHMA Keying). Traditional brass pin-tumbler rekeying (follower + pin kit). Standard door geometry: 1-3/8 to 1-3/4 in door thickness, 2-1/8 in cross-bore, 2-3/8 or 2-3/4 in backset (SC1 5-pin residential / SC4 6-pin commercial)

Standard / Grade
ANSI/BHMA Keying (SC1 / SC4)
Endurance / Pins
5-pin (SC1) / 6-pin (SC4)
Deadbolt / Tolerance
0.015 in pin depth increment
Door Prep Spec
2-1/8 in cross-bore
Exterior wood door jamb fitted with a heavy-gauge stainless steel strike plate and long structural screws.
Exterior wood door jamb fitted with a heavy-gauge stainless steel strike plate and long structural screws.
Standard / Grade
ANSI/BHMA Keying (SC1 / SC4)
Cycle Endurance
5-pin (SC1) / 6-pin (SC4) [Builders Hardware Manufacturers Association (BHMA)]
Deadbolt / Pin Spec
0.015 in pin depth increment [Builders Hardware Manufacturers Association (BHMA)]
Impact / Rekey Method
Traditional brass pin-tumbler rekeying (follower + pin kit)

What door prep and representative lock hardware fit SC1 / SC4?

Standard Door Geometry: 1-3/8 to 1-3/4 in door thickness, 2-1/8 in cross-bore, 2-3/8 or 2-3/4 in backset (SC1 5-pin residential / SC4 6-pin commercial) — Reference Series: Schlage F-Series, B60, Encode, Connect, Dexter.

What are the standard residential door cross-bore and backset dimensions?

North American residential exterior doors specify a 2-1/8 inch cross-bore, 1 inch edge bore, 2-3/8 or 2-3/4 inch adjustable backset, and 1 inch deadbolt throw across 1-3/8 to 1-3/4 inch door thickness.

Standard Residential Door Lock Cutout Measurements Door edge diagram showing 2-1/8 inch hole, 2-3/8 or 2-3/4 inch backset, 1-inch deadbolt throw, 3-inch strike plate screws, and Schlage vs Kwikset keyways. 2-3/8 or 2-3/4" 2-1/8" Door Hole Door thickness: 1-3/8" to 1-3/4" 1" Edge Hole + 1" Hardened Bolt Deadbolt Strength: Grade 1 vs Grade 2 Grade 1: 250,000 turns, 10 blows, 3" frame screws Grade 2: 150,000 turns, 5 blows (standard home lock) Common Home Keyways (5-Pin) Schlage C (SC1): 0.015 in pin steps · standard rekey Kwikset (KW1): 0.023 in steps · SmartKey quick rekey
Standard U.S. exterior door cutouts (2-1/8 in hole, 2-3/8 or 2-3/4 in backset, 1 in deadbolt throw) alongside Grade 1 and Grade 2 lock durability ratings.

How do ANSI/BHMA A156.36 Grade 1, 2, and 3 standards compare?

Side-by-side matrix comparing deadbolt hammer-strike impact ratings, 250,000 vs 100,000 test cycle limits, and Schlage SC1 vs Kwikset KW1 cylinder keyway tolerances.

ANSI/BHMA A156.36 Grade 1-3 & SC1/KW1 residential lock standards
Standard / KeywayGrade / ProfileCycles / PinsBolt / Spec
ANSI/BHMA A156.36 Grade 1 Residential/Commercial Deadbolt Grade 1 250,000 cycles 1 inch minimum solid/hardened pin throw
ANSI/BHMA A156.36 Grade 2 Light-Commercial / Heavy Residential Deadbolt Grade 2 150,000 cycles 1 inch minimum throw
ANSI/BHMA A156.36 Grade 3 Standard Residential Deadbolt Grade 3 100,000 cycles 1 inch throw (or 5/8 in legacy latch)
Schlage C Keyway (Ilco SC1 5-Pin / SC4 6-Pin) SC1 / SC4 5-pin (SC1) / 6-pin (SC4) 0.015 in pin depth increment
Kwikset Keyway (Ilco KW1 5-Pin / SmartKey) KW1 / SmartKey 5-pin (KW1) / 6-pin (KW10) 0.023 in pin depth increment

FAQ

Clear answers to 8 common repair, safety, cost, and licensing questions backed by official government records and manufacturer manuals.

How does ANSI/BHMA A156.36 distinguish Grade 1, Grade 2, and Grade 3 deadbolts?

Grade 1 endures 250,000 cycles and 10 blows at 75 ft-lbs, Grade 2 endures 150,000 cycles and 5 blows, and Grade 3 handles 100,000 cycles and 2 blows.

What is standard US residential door prep for deadbolts?

Most US exterior residential doors use a 2-1/8 in cross-bore, 1 in edge bore, 1-3/8 to 1-3/4 in thickness, and adjustable 2-3/8 or 2-3/4 in backset.

How long should strike plate screws be on an exterior deadbolt?

Anchor heavy-duty strike plates with 3-inch #10 structural wood screws reaching into wall framing studs rather than relying solely on short 3/4-inch jamb trim screws.

What is the difference between Schlage SC1 and Kwikset KW1 keyways?

SC1 uses 5 pins with 0.015 in depth increments (depths 0-9), while KW1 uses 5 pins with 0.023 in steps (depths 1-6) and optional 15-second SmartKey rekeying.

How can you spot a $19 locksmith bait-and-switch ad?

FTC consumer alerts warn against $15-$29 dispatch ads using unmarked subcontractors who demand cash and insist on drilling standard pin-tumbler deadbolts instead of picking them.

Which US states require centralized state locksmith licensing?

Eleven states enforce centralized boards (AL, CA, IL, LA, MD, NC, NJ, OK, OR, TX, VA), plus CT DCP, NV sheriff cards, and NYC DCWP; TN, NE, and FL have no statewide license.

Do residential smart deadbolts use the same bore size?

Yes; Schlage, Kwikset, and Yale ANSI/BHMA smart deadbolts fit standard 2-1/8 in cross-bores and 1 in deadbolt throws when door alignment is square.

Who should NOT force a binding smart deadbolt motor?

If a motorized deadbolt stalls or flashes low-battery alerts, adjust the strike pocket depth and swap fresh AA alkaline batteries rather than forcing internal drive gears.

Related guides

Sources

  1. BHMA Certified Products Directory (ANSI/BHMA A156.2 & A156.36 Grade 1/2/3 Locks) — Builders Hardware Manufacturers Association (BHMA), A156.2 / A156.36 (retrieved 2026-11-23)